FiltraCore Asia’s LFX-CPLEAT-PTFE™ PTFE Membrane Pleated Cartridge platform is engineered for aggressive chemical processes, critical gas filtration, solvent handling and corrosive liquid applications where chemical inertness, ultra-low extractables and stable absolute retention are essential. Constructed using expanded PTFE membrane technology with rigid polypropylene or fluoropolymer support structures depending on variant, these cartridges provide exceptional chemical resistance, high structural strength and reliable particulate control across a wide range of demanding operating environments.

The PTFE membrane architecture delivers excellent gas flow characteristics, enabling efficient filtration of compressed air, nitrogen, process gases, fermentation gases and sterile venting applications while maintaining very low differential pressure and stable contaminant retention. In liquid service, the membrane’s chemical stability enables long filtration cycles and predictable retention behaviour in systems handling strong acids, bases, oxidisers, solvents and high purity chemical intermediates.

With thermal-bonded, adhesive-free construction, LFX-CPLEAT-PTFE™ cartridges eliminate binder migration and support consistent performance in high purity and corrosive environments. The fully supported pleated membrane structure maintains pleat integrity under high flow rates, elevated temperatures and aggressive chemical exposure, ensuring dependable filtration performance across both gas and liquid process systems.

The LFX-CPLEAT-PTFE™ Series includes specialised variants engineered for specific operating requirements across chemical processing, pharmaceutical production, semiconductor manufacturing and industrial gas systems. These include hydrophobic PTFE cartridges for gas and vent filtration, hydrophilic PTFE cartridges for aggressive aqueous chemical liquids, sterilising grade PTFE membrane cartridges for critical pharmaceutical processes, solvent and chemical process PTFE cartridges for corrosive liquid filtration, sterile tank vent PTFE cartridges for microbial barrier protection and fully fluoropolymer cartridges designed for ultra-corrosive chemical environments. Selected variants are also available in wetted packaging to enable rapid membrane wetting and integrity testing for liquid filtration applications.

The current LFX-CPLEAT-PTFE™ platform includes the following specialised variants:

LFX-CPLEAT-PTFE-FLUORO™ – All fluoropolymer PTFE membrane cartridge for ultra-corrosive chemical service
LFX-CPLEAT-PTFE-HPOGAS™ – Hydrophobic PTFE membrane cartridge for gas and vent filtration
LFX-CPLEAT-PTFE-HPILIQUID™ – Hydrophilic PTFE membrane cartridge for aggressive chemical liquids
LFX-CPLEAT-PTFE-CHEM™ – PTFE membrane cartridge for solvent and chemical process filtration
LFX-CPLEAT-PTFE-STVENT™ – Hydrophobic PTFE cartridge for sterile tank vent protection
LFX-CPLEAT-PTFE-STERILE™ – Sterilising grade PTFE membrane cartridge for critical gas filtration

Designed to interface seamlessly with industry-standard filter housings, LFX-CPLEAT-PTFE™ provides a reliable, high-performance upgrade path for facilities requiring sterile gas protection, aggressive chemical filtration, solvent polishing and high purity venting while reducing change-out frequency and maintaining stable system performance.

Each cartridge is manufactured in a controlled cleanroom environment in accordance with Good Manufacturing Practices (GMP) under an ISO 9001:2015 certified Quality Management System. All cartridges are individually serialised and provide full material traceability.
The materials of construction comply with FDA food contact regulations as outlined in the U.S. Code of Federal Regulations (21 CFR). Components also meet the requirements of European Commission Regulation (EU) No. 10/2011 relating to plastic materials intended for food contact applications.

Available in industry-standard lengths and end-cap configurations, LFX-CPLEAT-PTFE™ cartridges are designed as drop-in replacements for many PTFE membrane cartridges from major OEMs including Pall® Emflon™, Parker Hannifin® Proflow™ / Fluoroflow™ PTFE Series and Amazon Filters SupaPore™ TP / SupaPore™ THB, subject to dimensional and application verification.

Technical Specifications

LFX-CPLEAT-PTFE-FLUORO™

Media & Construction: Hydrophobic PTFE membrane with PTFE support netting and PFA hardware
Micron Ratings: 30 nm, 50 nm, 0.1 µm, 0.2 µm, 0.45 µm, 1 µm, 5 µm
Nominal Lengths: 4", 10", 20", 30", 40"
Diameters: Outer Diameter: 69 mm (2.72"), 83 mm (3.3")
Filtration Area: HP: 1.12 m² (69 mm OD, 10"), 1.63 m² (83 mm OD, 10"); EP: 0.9 m² (69 mm OD, 10"), 1.51 m² (83 mm OD, 10")
End Styles / Seals: Seal materials available in E-FKM and F-FKM options
Temperature Limits: Maximum operating temperature 160 °C
Quality Assurance: Individually integrity tested cartridges manufactured in controlled production environments with full material traceability


LFX-CPLEAT-PTFE-HPOGAS™

• Media & Construction: Double layer hydrophobic PTFE membrane with polypropylene support structure
Micron Ratings: 0.22 µm + 0.22 µm
Nominal Lengths: 5", 10", 20", 30", 40"
Diameters: Outer Diameter: 69 mm (2.72")
Filtration Area: 0.65 m² per 10" filter cartridge
End Styles / Seals: Connection adaptors available with SS insert or PSU insert; seal materials available in Silicone, EPDM and FKM
Temperature Limits: Maximum operating temperature 80 °C
Maximum Operating Differential Pressure: 4 bar @ 20 °C; 2 bar @ 80 °C
Steam in Place (SIP): 135 °C for 30 minutes, up to 150 cycles
Bacterial Retention: LRV ≥ 7 Pseudomonas diminuta
Extractables: Less than 20 mg per 10" cartridge
Quality Assurance: Individually integrity tested cartridges manufactured in controlled environments with full material traceability


LFX-CPLEAT-PTFE-HPILIQUID™

• Media & Construction: Hydrophilic PTFE membrane with polypropylene support structure
Micron Ratings: 0.22 µm, 0.45 µm
Nominal Lengths: 5", 10", 20", 30", 40"
Diameters: Outer Diameter: 69 mm (2.72")
Filtration Area: 0.65 m² per 10" filter cartridge
End Styles / Seals: Seal materials available in Silicone, EPDM and FKM
Temperature Limits: Maximum operating temperature 80 °C
Maximum Operating Differential Pressure: 4 bar @ 20 °C; 2 bar @ 80 °C
Sterilisation: Autoclave 125 °C for 30 minutes up to 15 cycles; SIP 125 °C for 30 minutes up to 15 cycles
Extractables: Less than 20 mg per 10" cartridge
Quality Assurance: Manufactured in controlled cleanroom environments with full material traceability and individually integrity tested cartridges


LFX-CPLEAT-PTFE-CHEM™

• Media & Construction: Hydrophobic PTFE membrane with polypropylene support structure
Micron Ratings: 0.1 µm, 0.22 µm, 0.45 µm, 1 µm
Nominal Lengths: 5", 10", 20", 30", 40"
Diameters: Outer Diameter: 69 mm (2.72")
Filtration Area: 0.68 m² per 10" filter cartridge
End Styles / Seals: Seal materials available in Silicone, EPDM and FKM
Temperature Limits: Maximum operating temperature 80 °C
Maximum Operating Differential Pressure: 4 bar @ 20 °C; 2 bar @ 80 °C
Steam in Place (SIP): 135 °C for 30 minutes, up to 150 cycles
Pore Size: Gas filtration 0.01 µm; liquid filtration 0.22 µm
Bacterial Validation: Validated with Brevundimonas diminuta (ATCC 19146) at 10⁷ CFU/cm² (0.22 µm)
Extractables: Less than 20 mg per 10" cartridge
Quality Assurance: Manufactured in controlled cleanroom environments under ISO 9001 quality management systems, individually integrity tested with full material traceability
Compliance: Materials comply with USP <88> biological reactivity requirements for plastics


LFX-CPLEAT-PTFE-STVENT™

• Media & Construction: Hydrophobic PTFE membrane with polypropylene support structure
Micron Ratings: 0.1 µm, 0.22 µm, 0.45 µm, 1 µm, 3 µm, 5 µm, 10 µm
Nominal Lengths: 5", 10", 20", 30", 40"
Diameters: Outer Diameter: 69 mm (2.72")
End Styles / Seals: Seal materials available in Silicone, EPDM, NBR, FKM and E-FKM
Temperature Limits: Maximum operating temperature 80 °C
Maximum Operating Differential Pressure: 4 bar @ 20 °C; 2 bar @ 80 °C
Quality Assurance: Manufactured in controlled cleanroom environments under ISO 9001 quality management systems with individually integrity tested cartridges and full material traceability


LFX-CPLEAT-PTFE-STERILE™

• Media & Construction: Hydrophobic PTFE membrane with polypropylene support structure
Micron Ratings: 0.1 µm, 0.22 µm, 0.45 µm, 1 µm, 3 µm, 5 µm, 10 µm
Nominal Lengths: 5", 10", 20", 30", 40"
Diameters: Outer Diameter: 69 mm (2.72")
End Styles / Seals: Seal materials available in Silicone, EPDM, NBR, FKM and E-FKM
Temperature Limits: Maximum operating temperature 80 °C
Maximum Operating Differential Pressure: 4 bar @ 20 °C; 2 bar @ 80 °C
Sterilisation: Autoclave 125 °C for 30 minutes up to 100 cycles; SIP 125 °C for 30 minutes up to 30 cycles
Quality Assurance: Manufactured in controlled cleanroom environments under ISO 9001 quality management systems with individually integrity tested cartridges and full material traceability

Applications

LFX-CPLEAT-PTFE-FLUORO™

• Pharmaceutical products and high purity process fluids
• Solvents and aggressive chemical filtration including strong acids and bases
• Microelectronics and semiconductor process chemicals
• Chemically aggressive liquid filtration systems
• Fine chemical production and specialty chemical processing


LFX-CPLEAT-PTFE-HPOGAS™

• Compressed air filtration
• Solvent filtration and solvent vapour systems
• Filling machine breathing filters
• Fermentation tank vent and breathing


LFX-CPLEAT-PTFE-HPILIQUID™

• Corrosive reagent filtration
• Strong oxidising chemical filtration
• Large infusion (LVP) sterile filtration
• Clarification filtration of organic solvents
• High viscosity liquid filtration
• Eye drop sterile filtration


LFX-CPLEAT-PTFE-CHEM™

• Chemically aggressive liquid filtration
• Solvents and strong acids and bases
• Fermentation process air and gas filtration
• Process air vent filtration
• Bulk gas filtration


LFX-CPLEAT-PTFE-STVENT™

• Tank air vent filtration
• Fermentation process feed air filtration
• Compressed gas filtration
• Hot DI water vent filtration
• Aggressive solvent, acid and alkaline process environments


LFX-CPLEAT-PTFE-STERILE™

• Chemically aggressive fluid systems
• Solvent filtration including strong acids and bases
• Fermentation process air and gas filtration
• Process air vent filtration
• Bulk gas filtration